PROJECT REPORT
Total Emittance and Hemispherical Spectral
Reflectance Test Report
DSET Report #: 5017501, May 29, 1998
1.0 INTRODUCTION
This report presents results of total emittance and spectral reflectance measurements on
the following six coatings on metal coded as:
2.0 TEST METHODS AND PROCEDURES;
Emittance
Near-normal infrared reflectance measurements were performed in accordance with ASTM
E408-71 (reapproved 1990), method A. A Gier Dunkle Instruments Infrared Reflectometer
Model DB 100 was utilized for the measurements.
Inside the detector portion are two semi-cylindrical cavities. One of the cavities is
heated by an electrical heater and the other stabilizes at approximately room temperature.
Thus, the two cavities are maintained at different temperatures. As the cavities rotate,
the sample is alternately irradiated at 13 Hz. A vacuum thermocouple views the sample
through an optical system that focuses through slits in the ends of the cavities. The
detector receives energy emitted by the sample and energy reflected by the sample. Only
the reflected energy contains an alternating component as the sample is alternately
irradiated by the hot and cold cavities. An amplifier is synchronized with the cavity
rotation to pass only the desired alternating signal, which is then rectified and
filtered. The zero and gain are set with standards of known emittance. The calibration is
rechecked at several intervals during the measurement. Hemispherical emittance was
converted from normal emittance by using equations provided by the National Fenestration
Rating Council in NFRC 301-93.
Reflectance
Hemispherical spectral reflectance measurements were performed in accordance with ASTM
Standard Test Method E903-88 (1992). The measurements were performed with a Beckman 5240
Spectrophotometer utilizing an integrating sphere (Fig A1.3 of E903-88 (1992)). Total
reflectance measurements were obtained in the solar spectrum from 2500nm to 300nm at an
incident angle of 15 degrees. The measurements employ a detector-baffled, wall-mounted
integrating sphere that precludes the necessity of employing a reference standard except
to define the instruments 100% line. The measurements are properly denoted as being
hemispherical spectral reflectance.
3.0 OBSERVATIONS, DEVIATIONS AND WAIVERS
All measurements were performed on the uncoated surface. The values reported for emittance
represent the average of at four measurements.
4.0 RESULTS
EMITTANCE |
|||
|
|
|
|
| ULTRA KOTE | .06 | .94 | .89 |
| SNOWBRITE | .06 | .94 | .89 |
| INSULKOTE | .06 | .94 | .89 |
| PERMAKOTE | .07 | .93 | .88 |
| PERMAKOTE PLUS | .06 | .94 | .89 |
| ULTRA KOTE XL | .07 | .93 | .88 |
| REFLECTANCE | |
| Specimen Code | % Reflectance |
| ULTRA KOTE | 83.0 |
| SNOWBRITE | 83.7 |
| INSULKOTE | 81.5 |
| PERMAKOTE | 82.7 |
| PERMAKOTE PLUS | 81.3 |
| ULTRA KOTE XL | 81.7 |






NATIONWIDE's CONTACT INFORMATION: Business Hours: (M-F 8am-5pm EST) |
||
Telephone: 941.753.7500 U.S. Toll Free: 1.800.423.7264 Fax: 941.753.1773 (24 Hour Dedicated Fax) |
||
|
NATIONWIDE CHEMICAL COATING MFRS., INC. |
|
7106 24th Court East |
||
Sarasota, Florida U.S.A. 34243 |
||
E-mail: info@natcoat.net Web: webmaster@natcoat.net |
||
|
|
||
EXCLUSIVITY: Some Nationwide Products are sold Exclusively by Dealers and/or Distributors in Select Areas and Regions. |
||
LEAKS: Leaks resulting from acts of providence, owner or their agents, are not the responsibility of NCCMI and under no circumstances shall NCCMI be liable in any respects to the building, its occupants, its contents or for any consequential or incidental damages. Leaks are required to be repaired prior to the application of any coating and therefore are not covered under any warranty. |
||
| LABOR: Products Warranties are Limited to Material Only (see Limitations below), Labor is not included. Nationwide does not Warranty for Labor of any Kind. | ||
| LIMITATIONS: Any implied warranty, including warranty of fitness for a particular use or purpose, and warranty of merchantability, is limited in duration to the express warranty based on the Individual Product's Warranty, unless a shorter period is permitted by law. If no Warranty is stated for a specific product then the maximum warranty will be One Year from date of Purchase. If a Product has a specific Warranty and a Warranty was not applied for using a Warranty Registration Certificate, the maximum warranty will be One Year from Date of Purchase. NCCMI shall not be liable for incidental or consequential damages or for damage to the building, its contents, or its occupants. NCCMI's liability is limited to the reasonable replacement cost of product that has been fully paid for and shall be limited to defective product in the affected area only, whether any claim against it is based upon strict liability, negligence, breach of warranty or any other theory or cause of action. Venue in reference to any Product of Nationwide shall be Manatee County, Florida, U.S.A. | ||
| DISCLAIMER: Information presented on this Web Page or any other Web Page on Nationwide Chemical Coating Mfrs., Inc. Web Site has been compiled by sources to be reliable, and is accurate and reliable to the best of our knowledge and belief, but is not guaranteed to be so. | ||
| Copyright ©1998-2010 NATIONWIDE CHEMICAL COATING MFRS., INC. | ||